ELECTROPHORESIS SET UP

Enquire Now
Category:

Features:-

• Small footprint
• Spacious Dark Room
• High Resolution Camera
• White illumination, Trans UV, EPI UV
• Low cost

Technical Specification:-

  • UV Transilluminator : 312NM
  • Maximum Viewing Area : 21 x 26 CM
  • TRANS- UV
  • EPI- UV
  • EPI – VIS
  • Horizontal apparatus length 18-20cm, Breadth 5-7.5cm, 40-60 samples, multichannel pipette compatible combs and gel caster.
  • Camera : Digital
  • Image Resolution (Pixels) : 16MP
  • Vertical gel apparatus: 10 – 12 cm (Length) x 8 – 10 (Breadth) x8- 12cm(Height), 5-10 samples, glass plate (10 x10 cm), comb capacity of 35μl – 50μland gel caster.
  • Lens : Manual
  • 1D Gel Analysis Software: Basic Import common image types up to 48bit, 16 Bit Grey levels Image pre-processing.
  • Manual lane detection
  • Manual and Automatic band detection
  • Manual correction for lanes and bands
  • 6 methods for background noise reduction
  • Rf correction to correct distorted gels
  • MW Calibration using MW standards, Standard editor Quantification for bands and lanes
  • Gel imaging system with UV trans-illuminator (white light and UVlight), built in with 5MP – 10MP camera; 1D Gel analysis Soft-ware. Power pack(output 10 – 300 V) with output terminals, timer, 3 digit LED display and start/stop function.

SPECIFICATION

Technical Specification:-

  • UV Transilluminator : 312NM
  • Maximum Viewing Area : 21 x 26 CM
  • TRANS- UV
  • EPI- UV
  • EPI – VIS
  • Horizontal apparatus length 18-20cm, Breadth 5-7.5cm, 40-60 samples, multichannel pipette compatible combs and gel caster.
  • Camera : Digital
  • Image Resolution (Pixels) : 16MP
  • Vertical gel apparatus: 10 – 12 cm (Length) x 8 – 10 (Breadth) x8- 12cm(Height), 5-10 samples, glass plate (10 x10 cm), comb capacity of 35μl – 50μland gel caster.
  • Lens : Manual
  • 1D Gel Analysis Software: Basic Import common image types up to 48bit, 16 Bit Grey levels Image pre-processing.
  • Manual lane detection
  • Manual and Automatic band detection
  • Manual correction for lanes and bands
  • 6 methods for background noise reduction
  • Rf correction to correct distorted gels
  • MW Calibration using MW standards, Standard editor Quantification for bands and lanes
  • Gel imaging system with UV trans-illuminator (white light and UVlight), built in with 5MP – 10MP camera; 1D Gel analysis Soft-ware. Power pack(output 10 – 300 V) with output terminals, timer, 3 digit LED display and start/stop function.